ProteoRed - Instituto Nacional de Protemica Jul 30th, 2010 
ProteoRed Multi-centric Experiment 6 page


Last update: 26-Feb-2010     
Participants - PME 5

Back to PME-5 main page
 
 
 

Participants and quantitation approaches:

                   
                   
     
     
1 CNB X X            
2 CBM           X X  
3 PCM-UCM   X            
4 CIB               X
5 CIC bioGUNE             X  
6 CIMA   X           X
7 UPV-EHU             X  
8 LP-CSIC/UAB   X            
9 HUVH X       X     X
10 PCB   X     X X X  
11 UPF   X            
12 IBB-UAB               X
13 UB         X X   X
14 CIC X              
15 INIBIC   X            
16 CIPF   X            
17 UA         X      
18 UV                
19 UCO   X   X        
20 I+CS   X   X        
21 CMU     X          
22 UNAM   X            
                   
                   
                   

 

Participants and mass spectrometers:

                   
                   
     
1 CNB       4800 MALDI-TOFTOF
(Applied) for iTRAQ
HCT Ultra 3D ion-trap
(Bruker) for ICPL
 
2 CBM         LCQ DECA XP
(Thermo)
 
3 PCM-UCM       4800 MALDI-TOFTOF
(Applied) for iTRAQ
   
4 CIB       X    
5 CIC bioGUNE     Q-TOF Premier
(Waters)
     
6 CIMA     QTOF Micro
(Waters)
     
7 UPV-EHU     Synapt
(Waters)
     
8 LP-CSIC/UAB           LTQ Ion Trap
(Thermo)
9 HUVH         Ion Trap Esquire-Ultra
(Bruker)
 
10 PCB LTQ Orbitrap Velos
(Thermo)
  QTOF Micro
(Waters)
4700 MALDI-TOFTOF
(Applied)
   
11 UPF LTQ Orbitrap XL and Velos
(Thermo)
         
12 IBB-UAB       Ultraflex Tof-Tof
(Bruker)
   
13 UB LTQ Orbitrap Velos
(Thermo)
      LCQ IonTrap
(Thermo)
 
14 CIC         LCQ DECA XP
(Thermo)
 
15 INIBIC       4800 MALDI-TOFTOF
(Applied)
   
16 CIPF     QSTAR
(Applied)
     
17 UA         Ion Trap XCT plus
(Agilent)
 
18 UV            
19 UCO LTQ Orbitrap
(Thermo) for iTRAQ
4000 Qtrap
(Applied) for MRM
  4800 Plus MALDI-TOFTOF
(Applied)
  4000Qtrap
(Applied) for iTRAQ
20 I+CS   4000 Qtrap (Applied) fro MRM   4800 Plus MALDI-TOFTOF
(Applied) for iTRAQ
   
21 CMU

LTQ Orbitrap Velos
(Thermo)

         
22 UNAM   3200 Qtrap
(Applied) for iTRAQ
       
                   
                   
                   
Back to PME-5 main page

 

Participants and data analysis software:

                   
                   
     
1 CNB   X (for iTRAQ)   X (for ICPL) X (for iTRAQ)                          
2 CBM           X                        
3 PCM-UCM   X (for iTRAQ)                                
4 CIB                               X    
5 CIC bioGUNE                   X (with Expression module for label-free)                
6 CIMA         X   X     X (for spot identification)                
7 UPV-EHU                   X (with Expression module for label-free)                
8 LP-CSIC/UAB         X (for iTRAQ)     X (for iTRAQ) X (for iTRAQ)                  
9 HUVH           X         X (for ICPL)           X (for DIGE)  
10 PCB           X           X (for labe-free intensity based) X (for iTRAQ) X (for iTRAQ) X (for label-free spectral count)      
11 UPF X (for iTRAQ)                                  
12 IBB-UAB                                 X (for DIGE)  
13 UB           X                        
14 CIC                                   X (for ICPL)
15 INIBIC   X (for iTRAQ)     X (for iTRAQ)                          
16 CIPF   X (for iTRAQ)                                
17 UA           X                        
18 UV                                    
19 UCO X (for MRM) X (for iTRAQ)                                
20 I+CS   X (for iTRAQ) X (for MRM)                              
21 CMU         X (for TMT)                          
22 UNAM   X (for iTRAQ)                                
                   
                   
                   
Back to PME-5 main page

 


Working Group 1 | Working Group 2 | Working Group 3 | Working Group 4
Working Group 5 | Working Group 6 | Working Group 7

@2009 ProteoRed. All rights reserved. Credits